// SaltyLab — Kill Switch Mount
// 60×60×40mm PETG
// 22mm panel-mount emergency stop button
// Mounts to 2020 extrusion, easily reachable
// ============================================
include <dimensions.scad>
mount_w = 60;
mount_d = 60;
mount_h = 40;
panel_h = 3; // Panel face thickness
module kill_switch_mount() {
difference() {
union() {
// Main body (angled face for visibility)
hull() {
translate([-mount_w/2, 0, 0])
cube([mount_w, mount_d, 1]);
translate([-mount_w/2, 5, mount_h])
cube([mount_w, mount_d - 5, 1]);
}
// 2020 extrusion mount bracket (back)
translate([-15, mount_d, 0])
cube([30, 10, 20]);
}
// Kill switch hole (22mm, through angled face)
translate([0, mount_d/2, mount_h/2])
rotate([10, 0, 0]) // Slight angle for ergonomics
cylinder(d=kill_sw_dia + tol, h=panel_h + 2, center=true, $fn=50);
// Interior cavity (hollow for switch body)
translate([-kill_sw_dia/2 - 3, 5, 3])
cube([kill_sw_dia + 6, mount_d - 10, mount_h - 3]);
// Wire exit hole (bottom)
translate([0, mount_d/2, -1])
cylinder(d=10, h=5, $fn=25);
// Extrusion bolt holes (M5, through back bracket)
for (z = [7, 15]) {
translate([-20, mount_d + 5, z])
rotate([90, 0, 0])
cylinder(d=m5_clear, h=15, center=true, $fn=25);
}
// Label recess ("EMERGENCY STOP" — flat area for sticker)
translate([-25, 5, mount_h - 1])
cube([50, 15, 1.5]);
}
}
kill_switch_mount();